Sample Testing

Quotex

Prove the Automaxion Technology in your application

If you would like to know if the automaxion mill can perform better than your current methods for your application, why not send us some samples so we can prove it to you. Call or email us first, of course. Here are some things to consider...

Cocrystal screening

Challenge us with a system you are familiar with, or something new. Why not try:-

  • varying the stoichiometry for one cocrystal former
  • several cocrystal formers
  • various solvents (if any) for SDG or SAG
  • scale-up from mg to g scales

Crystal Morphology by Milling

Challenge us to mill your solids under various conditions:-

  • Time
  • Temperature
  • Intensity

Milling for Particle Size Reduction, Small Amounts for Seed Crystals that Cannot be Micronised, Dispersion, etc.

If you have a material you want milled or dispersed, we can demonstrate:-DistriPlot

  • Dry milling
  • Wet milling with different solvents
  • Wet milling with different dispersants
  • Comminution
  • Scale-up potential from g scale
  • Milling under pressure

General Conditions

We can run several standard size vials at no charge including

  • Wheaton Glass Pressure vials with valve (34 mm diameter)
  • LC/GC vials (11.5 mm diameter)
  • EPA vials (27.5 mm diameter)
  • Other jars of 41 mm diameter

If you would like us to run samples in your specific vial, we would charge to make the vial adapter. The maximum diameter of vial we can accomodate is aproximately 45 mm diameter. The number of vials is inversely proportional to their diameter.

Testing Automaxion Technology on a customers existing mill

If you have a suitable mill, we can supply vial adapters for the vials listed above for testing at your site. No modifications are required to your mill. The customer is responsible for shipping both too and from Automaxion (in France). There would be a nominal weekly charge and the customer is responsible for ensuring the adapters are returned in a  clean condition. Any repairs or cleaning required upon return will be charged to the customer.

Samples run at Automaxion's site

We can accomodate most requests and will run many tests for free especially if standard components and conditions are used. We prefer to work only with non-hazardous materials but where samples remain in the customer vials throughout there time at Automaxion (i.e. only filled and opened on the customers site), we may be able to run them. The customer is responsible for shipping both too and from Automaxion (in France)

For a large number of samples, a per-sample charge will apply.

Samples run at customers site

It is possible to run samples on the Automaxion system at the customers site, with or without an Automaxion representative being present. There would be a nominal weekly charge and the customer is responsible for ensuring the mill is returned in a pristine and clean condition. Any repairs or cleaning required upon return will be charged to the customer. The customer would be responsible for shipping to and from the customers site. If you would like the assistance of Automaxion on-site, please let us know.

To discuss how we can meet your needs, please contact us.

Our Clients

 

umicore

 

Catalent

image348

image424

image12551

image4931

image11291

image1126

image1229

image1257


To Contact Us

Click Here

MousePointerFinger


Industries

 

Pharmaceuticals

Crop Protection

Catalysts

Ceramics

Pigments

Inks

Foodsuffs

Personal Care

Cosmetics

Automaxion Limited. Registered in England No. 5396554.      Automaxion SARL. Registered in France SIRET 48520026500018
UK Registered Office: Winnington House, Woodberry Grove, North Finchley, LONDON, N12 0DR

Automaxion does not claim rights to Logo’s or endorse services or products from other organisations that may appear on this site